JIYANG CABLE CO.,LTD
|
Payment Terms: | T/T |
Place of Origin: | Hebei, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Salesjycable[at]hotmail[dot]com
Jacket material | PVC | Wire maximum diameter, | 500 mm |
insulating material, | Plastic insulated power cable | Core material, | red copper wire |
voltage classes, | Low and medium voltage power cables 35kv and below | nominal cross section, | 1-630 mm2 |
type | |||
insulation thickness | 50 mm | ||
cores | 1-20 |
1,oducts according to GB/T12706-2002 national standard
2, Partial discharge test: rated voltage Uo for and kv and below cable put power "and PC; Rated voltage Uo for more than eighteen kv power cable put < 5 PC.
3, 20ohm conductor dc resistivity: copper core acuities were 0.017241 OHM best callus induction/mo aluminium acuities were 0.028 OHM best callus induction/m.
4, combustion performance(flame retardant cable) according to GB/T18380-2001 standard test
Operating characteristic
1\Cable highest long-term working temperature is 90 ohm
2\Cable the ambient temperature under installation should not below 0 ohm, cable bending radius should be more than twenty times of cable diameter.
3\In case of short circuit, the highest temperature of the conductor shall not be more than 250 ohm, duration is no more than 5 seconds
4\Laying temperature shall not be lower than 0 ohm.
5\Short circuit, the highest temperature of the conductor shall not be more than 160 ohm, duration is no more than 5 seconds.
6\Cable used in rated voltage 0.6/1\1.8/3\3.6/6\6/6\6/10\8.7/10\8.7/15\12/20\21/35\26/35KV Power transmission and distribution system.
7\YJV YJLV suitable for indoor and outdoor installation, can withstand certain laying traction, but unable to bear external mechanical forces of situations. Single core cable are not allowed in the pipe laying in ferromagnetic materials. YJV22, YJLV22 suitable for buried laying, able to bear external mechanical forces effect, but unable to bear large pulling force.
Production Range,
Type | Cores | Rated voltage KV | |||||
0.6/1 | 1.8/3 | 3.6/6,6/6 | 6/10,8.7/10 | 8.7/15~12/20 | 18/20~26/35 | ||
Conductive wire core nominal section MM2 | |||||||
YJV | 1 | 1.5~800 | 10~800 | 25~1200 | 25~1200 | 35~1200 | 50~1200 |
3 | 1.5~300 | 10~300 | 25~300 | 25~300 | 35~300 | - | |
4 | 4~240 | - | - | - | - | - | |
YJV | 1 | 2.5~1000 | 10~1000 | 25~1200 | 25~1200 | 35~1200 | 50~1200 |
3 | 2.5~300 | 10~300 | 20~300 | 25~300 | 35~300 | - | |
4 | - | - | - | - | - | - | |
YJV22 | - | - | - | - | - | - | - |
3 | 4~300 | 4~300 | 25~300 | 25~300 | 35~300 | - | |
4 | 4~240 | 4~240 | - | - | - | - | |
YJV23 | - | - | - | - | - | - | - |
3 | 4~300 | 4~300 | 25~300 | 25~300 | 35~300 | - | |
4 | 4~240 | 4~240 | - | - |
Oil resistant cable: used for numerical control machine tool equipment electrical connection
Waterproof cable: used for outdoor, underground pipelines, CMC channel and humidity larger environment
Rat termite cable: used for important signal transmission cable, power cable, can effectively prevent the rats, ants and insects chewing on cable
Resistance to low temperature cable: used for outdoor, cold storage equipment working environment, the minimum resistance low temperature - degrees, in low temperature environment cable can still keep soft condition, no crack, convenient operation.
Environmental protection cable: the environmental protection plastics, widely used in environmental protection requirements of strict place.
Flame retardant cable: the flame retardant plastic, in case of fire can effectively prevent fire spread along the wire.
Integrated cable: according to the customer request or sample production lines, the various equipment line, line integrated in a piece of wire inside, plus sheath of protection wiring beautiful and extend cable service life. According to the different use environment can choose oil resistant sheath, waterproof jacket, resistance to low temperature sheath, ring protective sleeve, general PVC sheathed, elastic sheath, flame retardant sheath and so on many kinds of types for wiring operation to provide adequate agility and convenience
Our company production and operation 3.6/6 kv - 26/35 kv crosslinking of polyvinyl chloride (PVC) power cable, 0.6/1 kv crosslinking of polyvinyl chloride (PVC) power cable, plastic insulation control cable, 10 kv / 35 kv overhead insulated cable, PVC insulated wire, low smoke zero halogen, flame retardant, refractory, power cable, mine rubber sleeve soft cable, general rubber sleeve soft cable, computer cable, signal cable, coaxial cable, waterproof cable, communication cable, insulated conductor.
insulated conductor: BV BVR RV BLV
Flame retardant fire-resistant wire:ZRBV ZABV ZBBV ZCBV ZDBV ZRBVR ZRRV
Sheath line:RVV RVVP
Cross-linking power cable:VV\VV22\YJV\YJV22\VLV.VLV22\YJLV\YJLV22
Flame retardant power cable:ZRVV\ZRVV22\ZRYJV\ZRYJV22\ZRYJLV\ZRYJLV22
Refractory power cable:NHVV\NHVV22\NHYJV\NHYJV22
The low smoke, zero halogen series:WDZB-YJY\WDZB-YJY22\WDZB-VV\WDZB-VV22\WDZB-YJLY\WDZB-YJLY22
cabtyre cable:YZ YC YH YCW YZW YQ YQW
Flame retardant rubber sleeve cable:ZC-YZ\ZC-YC\ZC-YH\ZC-YZ\ZA-YC\ZA-YH\ZA-YZW\ZC-YCW\ZC-YZW
Screened control panel cable:KVV KVV22 KVVP KVVP22 KVVP2 KVVP2-22 KVVR KVVRP
computer cable:
DJYPV/DJYP2V/DJYP3V/DJYVP/DJYVP2/DJYVP3/DJYPVP/DJYP2VP2 DJYP3VP3/DJYPVR/DJYP2VR/DJYP3VR/DJYVPR/DJYVP2R/DJYVP3R/DJYPVPR DJYP2VP2R/DJYP3VP3R/DJYPV22/DJYP2V22/DJYP3V22/DJYVP22/DJYVP2-22 DJYVP3-22/DJYPVP22/DJYP2VP2-22/DJYP3VP3-22
communication cable:HYA HYV HYAV HYAC HYAT CPEV CPEV-S
Shielding communication cable:HYVP HYAP MHYVP MHYVP MHYVRP RVSP
Armore communication cable:
HYA53 MHYA32 MHYV22 MHYAV22 MHYAV32 HYAT53 HYV22 HYV32 HYA32 HYV53 HYVP22 HYAP22 HYAP32 MHYVP22 MHYVP32 MHYVRP22 MHYVRP32
Flame retardant communication cable:ZR-HYA ZRA-HYA ZA-HYA ZRC-HYA WDZ-HYA ZR-YJYR